TheBotique

iaiops-renewables

Renewables edition of iaiops — solar PV plants and wind farms: PV inverters / string combiners and wind-turbine controllers over Modbus (SUN2000 / Growatt / generic wind-turbine templates), plant SCADA over OPC-UA, and MQTT-Sparkplug telemetry, plus the cross-protocol brain (PdM, downtime, OEE, alar

as observed 2026-10-18T21:45:32.509Z
Identifier
iaiops-renewables
Source
ClawHub
Version observed
0.31.0
Source repository
not published
Repository observation
No source repository listed
First observed here
2026-08-28T22:06:26.689Z
Observations recorded
7
Installs (reported upstream)
1
Weekly downloads (upstream)
1,905
Declared license
MIT-0

Observation history

2026-10-18T21:45:32.509Z

Fields that differed: changelog latestVersion

FieldBeforeAfter
changelog "iaiops 0.29.0: call-origin audit, OEE stop attribution, bearer-token sockets, CRA vulnerability handling, UK half-hourly meter analytics, companion-spec role hints. See CHANGELOG. "iaiops 0.31.0: serial ASCII instruments (15th protocol); MCP tools that read or write a host file are confined to the agent's roots (a write path could replace the audit DB before
latestVersion "0.29.0" "0.31.0"
2026-10-17T20:48:50.018Z

Fields that differed: changelog latestVersion summary

FieldBeforeAfter
changelog "0.28.0: MQTT/Sparkplug collectable; onboard's two journeys (devices / uns with a B1/B2 namespace fork)" "iaiops 0.29.0: call-origin audit, OEE stop attribution, bearer-token sockets, CRA vulnerability handling, UK half-hourly meter analytics, companion-spec role hints. See CHANGELOG.
latestVersion "0.28.0" "0.29.0"
summary "Renewables edition of iaiops — solar PV plants and wind farms: PV inverters / string combiners and wind-turbine controllers over Modbus (SUN2000 / Growatt / generic wind-turbine t "Renewables edition of iaiops — solar PV plants and wind farms: PV inverters / string combiners and wind-turbine controllers over Modbus (SUN2000 / Growatt / generic wind-turbine t
2026-09-17T19:21:46.965Z

Fields that differed: license description

FieldBeforeAfter
license null "MIT-0"
description "Renewables edition of iaiops — solar PV plants and wind farms: PV inverters / string combiners and wind-turbine controllers over Modbus (SUN2000 / Growatt / generic wind-turbine t null
2026-09-16T18:18:14.360Z

Fields that differed: changelog latestVersion

FieldBeforeAfter
changelog "router now routes to the pharma edition · contextual baselines · downtime attribution (D18) · alarm event-type clustering · device advisory matching · GxP crosswalk" "0.28.0: MQTT/Sparkplug collectable; onboard's two journeys (devices / uns with a B1/B2 namespace fork)"
latestVersion "0.27.0" "0.28.0"
2026-09-03T07:20:35.503Z

Fields that differed: changelog latestVersion

FieldBeforeAfter
changelog "verify determinism (executed model-free claim) · PLC program change baseline · pharma edition" "router now routes to the pharma edition · contextual baselines · downtime attribution (D18) · alarm event-type clustering · device advisory matching · GxP crosswalk"
latestVersion "0.26.0" "0.27.0"
2026-09-02T06:49:02.991Z

Fields that differed: changelog latestVersion

FieldBeforeAfter
changelog "- Expanded the protocol brain toolset with new meta and investigation commands: `protocols_supported`, `site_readiness`, `investigation_readiness`, `investigation_open`, `investig "verify determinism (executed model-free claim) · PLC program change baseline · pharma edition"
latestVersion "0.23.1" "0.26.0"

Correction

If you maintain this extension and believe anything above is inaccurate, request a correction. Corrections are published, and disputed entries are marked as disputed while under review.